Glossary

LIMS Glossary: Laboratory Terms Explained

55 terms that come up when labs choose, implement and audit a laboratory information management system, defined in plain English. New to the topic? Start with what a LIMS is.

#

21 CFR Part 11

21 CFR Part 11 is the US FDA regulation that sets the criteria under which electronic records and electronic signatures are treated as trustworthy, reliable and equivalent to paper records and handwritten signatures. It applies to records that other FDA regulations (such as GLP and GMP rules) require a company to keep. Key controls include system validation, secure computer-generated time-stamped audit trails, limiting access to authorized users, authority checks and signatures that are permanently linked to their records. The rule was issued in 1997, and FDA later published guidance on its scope and application.

A

Accessioning

Accessioning is the process of receiving a sample into the laboratory and registering it with a unique identifier, usually called an accession number. At accessioning the lab records who submitted the sample, what it is, when and how it was collected, the tests requested and its condition on arrival. A barcode label is normally printed at this step so the sample can be scanned at every later stage.

ALCOA+

ALCOA+ is a set of principles for data integrity stating that data must be Attributable, Legible, Contemporaneous, Original and Accurate, plus Complete, Consistent, Enduring and Available. The original five ALCOA attributes came from regulatory practice in the pharmaceutical industry, and the four additions are now widely referenced in data integrity guidance. In a LIMS, ALCOA+ is supported by unique user logins, audit trails, controlled time stamps, retention of original data and reliable backups.

Aliquot

An aliquot is a measured portion taken from a sample so that it can be tested, stored or sent elsewhere separately from the original. Each aliquot is a child of its parent sample and normally receives its own identifier and label. A LIMS keeps the parent-child lineage so that any result on an aliquot can be traced back to the original sample and its collection details.

ASTM LIS2-A2

LIS2-A2 is the CLSI standard that defines the message format for transferring orders and results between clinical laboratory instruments and information systems; it is commonly called the ASTM protocol because it was derived from ASTM E1394. Messages are built from records such as header (H), patient (P), order (O), result (R) and terminator (L). It is normally used with the companion low-level transport standard LIS1-A, derived from ASTM E1381. Many analyzers in clinical, veterinary and research labs still use it for instrument interfacing.

Audit Trail

An audit trail is a secure, computer-generated, time-stamped record of who created, modified or deleted a piece of data, when they did it and, where required, why. A compliant audit trail records the old and new values without overwriting or obscuring the original entry, and ordinary users cannot edit or switch it off. Audit trails are expected under 21 CFR Part 11, EU GMP Annex 11 and data integrity guidance, and reviewers use them to reconstruct the history of any result.

B

Barcode

A barcode is a machine-readable label that encodes a sample, container or item identifier so it can be scanned instead of typed. Linear (1D) barcodes such as Code 128 are common on tube labels, while 2D codes such as Data Matrix and QR hold more data in a smaller area and are often printed on the base of storage tubes. Scanning at each handoff reduces transcription errors and builds the sample's electronic history; RFID tags are an alternative that can be read without line of sight.

Batch Release

Batch release is the formal decision that a manufactured batch meets its specifications and was produced under GMP, so it can be supplied for sale or further use. The decision rests on QC test results, the review of the batch record and the closure of any deviations linked to that batch. In the EU a Qualified Person certifies each batch, while under US rules the quality control unit has the authority to approve or reject it.

C

Calibration

Calibration is the documented comparison of an instrument's readings against reference standards of known value, under specified conditions, to establish how far the instrument deviates and with what uncertainty. For results to be metrologically traceable, the reference standards must link to SI units through an unbroken chain of calibrations. Calibration is different from adjustment: an instrument can be calibrated and found to need adjustment, after which it is calibrated again. Labs keep calibration schedules, certificates and due dates for every instrument that affects results.

Certificate of Analysis (COA)

A Certificate of Analysis (COA or CoA) is a document issued by a testing or quality control laboratory confirming that a specific batch or lot was tested and showing the results against its specification. A typical COA lists the product, batch or lot number, tests performed, methods, acceptance limits, results, a pass or fail conclusion and an authorized signature with date. Buyers, regulators and downstream manufacturers rely on the COA as evidence of quality, so a LIMS usually generates it directly from approved results.

Chain of Custody

Chain of custody is the chronological, documented record of every person who collected, handled, transferred or stored a sample, from collection to final disposal. Each transfer records who released the sample, who received it, the date and time, and the sample's condition, usually on a chain of custody form signed at each step. An unbroken chain of custody is what makes results defensible in legal, forensic, environmental compliance and workplace drug testing contexts.

CLIA (Clinical Laboratory Improvement Amendments)

CLIA, the Clinical Laboratory Improvement Amendments of 1988, are US federal regulations that set quality standards for all laboratories testing human specimens for diagnosis, prevention or treatment of disease. The program is administered by the Centers for Medicare and Medicaid Services (CMS) together with the FDA and CDC, and its rules are at 42 CFR Part 493. Requirements depend on test complexity (waived, moderate or high complexity) and cover personnel, quality control, proficiency testing and inspections.

Cloud LIMS

A cloud LIMS is a laboratory information management system hosted on cloud infrastructure and accessed through a web browser, rather than installed on the lab's own servers. It is usually sold as software as a service (SaaS) on a subscription, with the vendor handling hosting, updates, backups and infrastructure security. Cloud deployment lowers upfront IT cost and makes multi-site access simpler, while the lab remains responsible for its own users, data and validation of intended use.

Computer Software Assurance (CSA)

Computer Software Assurance (CSA) is a risk-based approach, described in FDA guidance, for establishing confidence that software used in production and quality systems is fit for its intended use. The guidance was first issued as a draft in 2022 and is written for medical device manufacturers, although its principles are widely discussed across other GxP areas. CSA focuses testing effort on features that pose a high risk to product quality or patient safety and accepts lighter, less scripted testing and leaner documentation for lower-risk functions.

Computer System Validation (CSV)

Computer System Validation (CSV) is the documented process of showing that a computerized system does what it is intended to do, consistently and reproducibly, in its regulated environment. It typically covers user requirements, risk assessment, supplier assessment, configuration specifications, testing (often as IQ, OQ and PQ) and a validation summary report. CSV is expected for GxP systems under rules such as 21 CFR Part 11 and EU GMP Annex 11, and ISPE's GAMP 5 is the most widely used framework for a risk-based approach.

Control Chart

A control chart is a graph of quality control results plotted in time order against a center line (usually the mean) and control limits (usually the mean plus or minus 2 and 3 standard deviations). It shows whether a method is stable or whether a shift, trend or excess random error has appeared. In clinical labs the Levey-Jennings chart is the common form, and decision rules such as the Westgard rules are applied to it to accept or reject a run.

Corrective and Preventive Action (CAPA)

Corrective and Preventive Action (CAPA) is a quality process for investigating problems, finding their root cause and taking action so they do not happen again (corrective) or do not happen in the first place (preventive). A CAPA record normally links to the triggering deviation, complaint, audit finding or OOS result, and includes the investigation, actions, owners, due dates and a check that the actions were effective. Regulators and accreditation assessors routinely review CAPA records as evidence that a quality system works.

Critical Value

A critical value, also called a critical result or panic value, is a laboratory result that indicates a potentially life-threatening condition and must be communicated to the responsible clinician immediately. Labs define their own list of analytes and thresholds and a procedure for urgent notification. The notification is documented with who was informed, by whom, the date and time and, often, a read-back confirmation, and ISO 15189 expects labs to have such a procedure.

D

Data Integrity

Data integrity is the degree to which data are complete, consistent and accurate throughout their lifecycle, from creation through processing, review, reporting, archiving and destruction. Regulators such as the FDA, the UK MHRA and the WHO have published data integrity guidance, which commonly uses the ALCOA+ principles as the benchmark. In practice it depends on access controls, audit trails, validated systems, review of original data and a culture where errors are reported rather than hidden.

Delta Check

A delta check is an automated comparison of a patient's current test result with that patient's previous result for the same analyte within a defined time window. If the difference exceeds a set limit, the result is flagged for review because it may indicate a sample mix-up, a collection or analytical error, or a real clinical change. Delta checks are a standard part of result verification in clinical laboratories.

Deviation

A deviation is any departure from an approved procedure, specification, method or established standard. Deviations can be unplanned (an error or unexpected event) or planned (an approved, temporary change made in advance). Each deviation is documented, investigated for root cause and assessed for its impact on results or product quality, and significant ones lead to a CAPA.

E

Electronic Lab Notebook (ELN)

An Electronic Lab Notebook (ELN) is software that replaces the paper lab notebook for recording experiments, observations, protocols and results. ELNs are mainly used in research and development, where work is less structured and changes from experiment to experiment. A LIMS, by contrast, manages structured, repeatable sample testing, and many labs use the two together.

Electronic Signature

An electronic signature is a computer data compilation of any symbol or series of symbols that an individual executes, adopts or authorizes as the legally binding equivalent of a handwritten signature. Under 21 CFR Part 11, a signed electronic record must show the signer's printed name, the date and time, and the meaning of the signature (such as review, approval or authorship). Signatures must be linked to their records so they cannot be copied or removed, and non-biometric signatures must use at least two distinct identification components, such as a user ID and password.

F

FHIR (Fast Healthcare Interoperability Resources)

FHIR (Fast Healthcare Interoperability Resources) is an HL7 standard for exchanging healthcare data through modern web APIs, using modular data units called resources. Laboratory workflows typically use resources such as ServiceRequest for orders, Specimen, Observation for individual results and DiagnosticReport for the final report. FHIR data is exchanged as JSON or XML over RESTful HTTP, which makes it easier to integrate with web and mobile applications than older HL7 v2 messaging.

G

Good Laboratory Practice (GLP)

Good Laboratory Practice (GLP) is a quality system covering how non-clinical health and environmental safety studies are planned, performed, monitored, recorded, archived and reported. It is defined by the OECD Principles of GLP and by national rules such as US FDA 21 CFR Part 58, and in India compliance is monitored by the National GLP Compliance Monitoring Authority. GLP applies to regulated safety studies, so it should not be confused with general good practice in routine testing labs.

Good Manufacturing Practice (GMP)

Good Manufacturing Practice (GMP) is the set of regulations and guidelines that ensure products such as medicines, food and cosmetics are consistently produced and controlled to appropriate quality standards. The quality control laboratory is a core part of GMP, covering sampling, testing, specifications, records and batch release. Examples include US FDA 21 CFR Parts 210 and 211, EU GMP guidelines, WHO GMP and, in India, Schedule M of the Drugs and Cosmetics Rules; the US term cGMP stresses that practices must be current.

GxP

GxP is a collective term for the good practice quality guidelines and regulations used in life sciences, where x stands for the specific field. Common examples are Good Laboratory Practice (GLP), Good Manufacturing Practice (GMP), Good Clinical Practice (GCP) and Good Distribution Practice (GDP). Software used to create or manage GxP records is expected to be validated and to protect data integrity.

H

HL7 (Health Level Seven)

HL7 refers both to Health Level Seven International, a standards development organization, and to its family of standards for exchanging clinical and administrative healthcare data. HL7 version 2 messaging is the most widely used format for sending lab orders into a LIS or LIMS and returning results to hospital and clinic systems, for example with ORU result messages. The newer HL7 FHIR standard uses web APIs instead of pipe-delimited messages.

I

Instrument Interface

An instrument interface is the connection that transfers test orders and results electronically between a laboratory instrument and a LIMS or LIS, so results do not have to be retyped. Common methods are serial or network connections using ASTM or HL7 messages, parsing of result files the instrument exports, and vendor APIs. A unidirectional interface only sends results to the LIMS, while a bidirectional interface also receives worklists or answers the instrument's queries for pending tests.

IQ, OQ and PQ (Installation, Operational and Performance Qualification)

IQ, OQ and PQ are the three qualification stages used to show that equipment or a computerized system is fit for its intended use. Installation Qualification (IQ) verifies it was installed correctly according to specifications, Operational Qualification (OQ) verifies it operates as intended across its defined operating ranges, and Performance Qualification (PQ) verifies it performs consistently under real conditions of use. Each stage follows an approved protocol and ends with a documented report, and design qualification (DQ) is sometimes added before IQ.

ISO 15189

ISO 15189 is the international standard that specifies requirements for quality and competence in medical laboratories. It covers the full testing process, including sample collection, examination, result reporting, and the laboratory's management system, and it emphasizes risk to patients. The current edition is ISO 15189:2022, and accreditation bodies such as NABL in India accredit medical laboratories against it.

ISO/IEC 17025

ISO/IEC 17025 is the international standard that specifies general requirements for the competence, impartiality and consistent operation of testing and calibration laboratories. The 2017 edition is organized into structural, resource, process and management system requirements, covering topics such as method validation, measurement uncertainty, metrological traceability, reporting of results and control of data and information management. Accreditation to ISO/IEC 17025 by a recognized body, such as NABL in India, shows that a lab is competent to produce valid results.

L

Laboratory Execution System (LES)

A Laboratory Execution System (LES) is software that guides analysts step by step through approved test methods and SOPs at the bench, capturing data as each step is performed. It enforces the order of steps, checks entries and calculations in real time and records instrument readings, reagents and equipment used. An LES replaces paper worksheets and is often part of, or tightly connected to, a LIMS.

Laboratory Information Management System (LIMS)

A Laboratory Information Management System (LIMS) is software that manages a laboratory's samples, tests, results, workflows and reports in one controlled system. Typical functions include sample registration and tracking, test assignment, instrument data capture, result review and approval, quality control, inventory, reporting and audit trails. A LIMS replaces paper registers and spreadsheets, and supports compliance with standards such as ISO/IEC 17025, GMP and 21 CFR Part 11.

Laboratory Information System (LIS)

A Laboratory Information System (LIS) is software built for clinical and diagnostic laboratories, organized around patients, test orders and results reported to clinicians. It handles patient registration, specimen collection, analyzer interfaces, result verification, critical value notification, billing and reporting, and it usually connects to hospital and electronic medical record systems. The terms LIS and LIMS overlap, but LIS usually refers to patient-centric clinical work and LIMS to sample-centric testing in other sectors.

M

Measurement Uncertainty

Measurement uncertainty is a non-negative parameter that characterizes the dispersion of the values that could reasonably be attributed to the quantity being measured. It is usually reported as an expanded uncertainty with a coverage factor of k = 2, which corresponds to roughly 95 percent confidence for a normal distribution. ISO/IEC 17025 requires labs to identify contributions to uncertainty and evaluate it, and the Guide to the Expression of Uncertainty in Measurement (GUM) is the main reference for how to calculate it.

Method Validation

Method validation is the documented process of proving that an analytical method is fit for its intended purpose. It assesses performance characteristics such as specificity or selectivity, accuracy, precision, linearity and range, limit of detection, limit of quantitation and robustness. Pharmaceutical labs typically follow ICH Q2(R2), while under ISO/IEC 17025 labs validate non-standard and lab-developed methods and verify that they can correctly perform standard methods.

Multi-site LIMS

A multi-site LIMS is a single LIMS platform used by several laboratory locations, such as collection centers, regional labs and a central reference lab. It shares master data such as tests, methods and specifications across sites, while restricting each user's access to the sites and data they are authorized for. Management gets a combined view of workload and turnaround, and samples can be transferred between sites with their full history intact.

N

NABL (National Accreditation Board for Testing and Calibration Laboratories)

NABL (National Accreditation Board for Testing and Calibration Laboratories) is India's accreditation body for laboratories and a constituent board of the Quality Council of India. It accredits testing and calibration laboratories to ISO/IEC 17025 and medical laboratories to ISO 15189, as well as proficiency testing providers and reference material producers. NABL is a signatory to the ILAC and APAC mutual recognition arrangements, which supports acceptance of accredited Indian lab results in other countries.

O

On-Premise LIMS

An on-premise LIMS is installed on servers that the laboratory or its parent organization owns and operates, usually inside its own data center or network. The organization is responsible for hardware, operating systems, databases, backups, security patches, upgrades and disaster recovery. Some labs choose it for network isolation or internal IT policy, at the cost of higher upfront investment and in-house IT effort compared with a cloud LIMS.

Out of Specification (OOS)

An out of specification (OOS) result is a test result that falls outside the established specification or acceptance criteria for a material or product. In pharmaceutical QC, FDA guidance expects every OOS result to be investigated, starting with a laboratory investigation to check for analytical error before any wider manufacturing investigation. A result cannot be invalidated or retested away without a documented, scientifically justified reason.

Out of Trend (OOT)

An out of trend (OOT) result is a result that is still within specification but does not follow the expected pattern compared with earlier results, such as an unusual change between stability time points. OOT results can be an early warning of a product, process or method problem before an OOS result occurs. Labs define their own OOT criteria and statistical methods in procedures, and often use control charts or regression to detect them.

P

Proficiency Testing (PT)

Proficiency testing (PT) is the evaluation of a laboratory's performance against pre-established criteria by means of interlaboratory comparisons. A PT provider sends the same test items to many labs, compares each lab's results with the assigned value and reports a score, often a z-score. Accreditation bodies require regular PT participation, and in clinical labs the same activity is often called external quality assessment (EQA).

Q

QC Sample

A QC sample is a sample of known or expected composition that is analyzed alongside routine samples to show that a method is performing correctly. Common types include blanks (to detect contamination), control materials or laboratory control samples at known levels (to check accuracy), matrix spikes (a real sample with a known amount of analyte added, to measure recovery and matrix effects) and duplicates (to check precision). If QC results fall outside their acceptance limits, the results of the associated batch are not released until the cause is resolved.

Quality Management System (QMS)

A Quality Management System (QMS) is the formal set of policies, processes, procedures and records an organization uses to direct and control quality. In a laboratory it typically covers document control, training and competence, equipment, nonconformities and deviations, CAPA, internal audits, complaints and management review. ISO 9001 is the general QMS standard, while ISO/IEC 17025 and ISO 15189 include management system requirements specific to laboratories.

R

Reagent and Inventory Management

Reagent and inventory management is the tracking of reagents, reference standards, consumables and other lab supplies, including lot numbers, quantities, storage locations, preparation and expiry dates. It alerts staff before stock runs out or materials expire and blocks the use of expired lots. Linking each reagent lot to the tests it was used in lets the lab trace and assess results if a lot is later found to be faulty.

Role-Based Access Control (RBAC)

Role-based access control (RBAC) is a security model in which permissions are assigned to roles, such as analyst, reviewer or QA manager, and users receive access by being assigned to those roles. It makes it easier to give each person only the access their job needs and to enforce segregation of duties, for example so that the analyst who enters a result cannot also approve it. RBAC supports the authority checks expected under 21 CFR Part 11 and data integrity guidance.

S

Sample Lifecycle

The sample lifecycle is the full sequence of stages a sample passes through in a laboratory, from collection and registration to final disposal. Typical stages are collection, accessioning, receipt and inspection, aliquoting, testing, result review and approval, reporting, storage or retention, and disposal. A LIMS records the status, location and custodian of the sample at each stage so its history can be reconstructed at any time.

Scientific Data Management System (SDMS)

A Scientific Data Management System (SDMS) captures, catalogs and archives the raw data files produced by laboratory instruments and software, such as chromatograms, spectra and instrument reports. It stores those files with metadata so they can be searched and retrieved for review, audits or reprocessing, often for many years. Linking SDMS files to LIMS results lets reviewers see the original data behind each reported value.

Specification

A specification is a list of tests, references to analytical procedures and acceptance criteria (numerical limits, ranges or other criteria) that a material or product must meet to be considered acceptable for its intended use. Specifications are set for raw materials, in-process samples, finished products and stability samples. A LIMS stores specification versions and compares each result against the applicable limits automatically, flagging any failures.

Stability Study

A stability study tests a product at planned time points while it is stored under controlled conditions of temperature and humidity, to establish its shelf life or retest period and recommended storage conditions. For pharmaceuticals, protocols commonly follow ICH stability guidelines such as ICH Q1A(R2), which define long-term, intermediate and accelerated storage conditions. A LIMS schedules each time point pull, creates the required tests and trends results across the study.

Standard Operating Procedure (SOP)

A Standard Operating Procedure (SOP) is an approved, written set of step-by-step instructions for performing a routine activity in a consistent way. Lab SOPs cover activities such as sample receipt, test methods, equipment operation, cleaning, data review and handling of deviations. SOPs are version-controlled, reviewed periodically, and staff must be trained on the current version before using it.

T

Turnaround Time (TAT)

Turnaround time (TAT) is the elapsed time between a defined start point, such as sample collection or receipt in the lab, and a defined end point, such as the result being reported. Labs set TAT targets by test and priority, and clients and clinicians often judge a lab's service by them. Monitoring TAT by stage shows where delays occur, for example in receipt, testing or review.

W

Westgard Rules

Westgard rules are a set of statistical decision rules, developed by James Westgard, for deciding whether an analytical run is in control based on QC results plotted on a Levey-Jennings chart. Common rules include 1-2s (a warning when one result exceeds 2 standard deviations), 1-3s, 2-2s, R-4s, 4-1s and 10-x, which detect random or systematic error. Using several rules together improves error detection while keeping false rejections low.

Worklist

A worklist is an ordered list of samples and tests assigned to an analyst, workstation or instrument run. It often includes positions for calibrators and QC samples, and it can be sent electronically to an instrument so the analyzer knows which tests to run on each sample. Worklists help labs plan capacity and keep samples moving toward their turnaround targets.